CSMS RFID Non-Contact Switches

Non-Contact Solid State Monitored Safety Switches

 

- Performance Level PLe

- Up to 32 series circuits with PLe

- High coding level

- No external monitoring necessary

- Connection of return circuit start

- Output up to 250 mA per safety output

- Large diagnostic possibility

- 3 LEDs for status information

- Switching distance: 13 mm

- Dimensions: 110 mm x 30 mm x 15 mm

- IP 67


RRS Series - Without Additional Evaluation
Application Examples

Stand Alone With or Without Auto Start

 

In Series Without Auto Start

In Series With Auto Start

- Individual CSMS up to PL e
- Integrated evaluation of a return circuit and start button  with direct connection possible to contactors
- Series circuits with up to 32 sensors up to PL e
- Integrated return circuit evaluation
- Automatic start
- Direct connection to contactors
- Highly configurable system for
- Series circuits with up to 32 sensors up to PL e
- Integrated return circuit evaluation
- Manual start
- Direct connection to contactors
- Highly configurable system for
Part Numbers
Connection Type of Part Part Number Description Data Sheet
M12 Connector Actuator & Switch 607.5988.027 CSMS-SET-RRS-U-T
Switch Only 607.5986.022 CSMS-M-RRS-U-T
Actuator Only 607.5980.023 CSMS-S
Cable Actuator & Switch 607.5988.029 CSMS-SET-RRS-U-KA
Switch Only 607.5985.025 CSMS-M-RRS-U-KA
Actuator Only 607.5980.023 CSMS-S
R Series - For Safety PLC Evaluation

Application Examples

Stand Alone With or Without OSSD Sensor

 

In Series Without OSSD Sensor

In Series With OSSD Sensor

- Individual CSMS up to PL e

- Connection to an evaluation for ex. safety controller
- Optional connection to a safety sensor or safety
light curtain, with OSSD output to the first CSMS
possible

- Diagnostic Channel

- Series circuits with up to 32 sensors up to PL e
- Connection to an evaluation for ex. safety controller

- Highly configurable system

- Diagnostic Channel

- Series circuits with up to 32 sensors up to PL e
- Connection to an evaluation for ex. safety controller
- Optional connection to a safety sensor or safety
light curtain, with OSSD output to the first CSMS
possible
- Highly configurable system

- Diagnostic Channel

Part Numbers
Connection Type of Part Part Number Description Data Sheet
M12 Connector Actuator & Switch 607.5988.028 CSMS-SET-R-U-ST
Switch Only 607.5986.024 CSMS-M-R-U-ST
Actuator Only 607.5980.023 CSMS-S
Cable Actuator & Switch 607.5988.030 CSMS-SET-R-U-KA
Switch Only 607.5985.026 CSMS-M-R-U-KA
Actuator Only 607.5980.023 CSMS-S
Diagnostics
Accessories
Picture Type of Part Version Part Number Description
T Connector Automatic Reset 607.5989.036 T-PIECE AS
Manual Reset 607.5989.037 T-PIECE MS
Spacer For Actuator 607.3900.070 CSMS SPACER
For Switch 607.5989.044 CSMS SPACER

Diagnostic

Indicator

Base 607.5989.031 CSMS DIAGNOSTIC BASIS
Additional for 8 Binary Outputs 607.5989.032 CSMS DIAGNOSTIC 8 OUT

Connection Cables

.5 Meter 607.5989.038 AN-KAB.CSMS 0,5M G/G
1 Meter 607.5989.039 AN-KAB.CSMS 1M G/G
2 Meter 607.5989.040 AN-KAB.CSMS 2M G/G
5 Meter 607.5989.041 AN-KAB.CSMS 5M G/G
10 Meter 607.5989.042 AN-KAB.CSMS 10M G/G
20 Meter 607.5989.043 AN-KAB.CSMS 20M G/G